High power single-mode 1550nm 50W CW fiber lasers with compact design , high efficiency, near diffraction limited beam quality and maintenance free stable operation. They are widely used in laser pointing, marking, scientific research , dermatology treatment and other applications.
Download the datasheets here:
Product Overview
This equipment is a 1550nm continuous-wave fiber laser with integrated air-cooled structure. It features narrow spectral linewidth and excellent beam quality, equipped with standard SMA905 fiber output connector. Widely applied in fiber optic sensing, infrared optical testing, LiDAR, precision scientific research, infrared illumination and other fields. Compact size with 24V low-voltage DC power supply, stable operation and industrial-grade service life.
Core Optical Specifications
| Parameter Item | Technical Index |
|---|
| Wavelength | 1550 nm |
| Output Power | 50 W |
| Spectral Width (3dB) | <1 nm |
| Beam Mode | TEM00 |
| Operation Mode | CW (Continuous Wave) |
| Output Method | SMA905 |
| Output Core Diameter | 15 μm |
| Average Power Stability (rms) | <3% |
| M² Factor | <1.5 |
| Beam Diameter | 4.0 mm |
| Polarization | Random |
Electrical, Environmental & Mechanical Specifications
| Parameter Item | Technical Index |
|---|
| Operating Temperature | 10 ~ 35 ℃ |
| Service Life | 10000 hours |
| Power Consumption | <200 W |
| Working Voltage | DC 24V |
| Cooling Method | Air-cooled |
| Dimensions of Laser Head | ≤300×400×150 mm |
Key Advantages
Narrow linewidth design with 3dB spectral width less than 1nm, excellent wavelength consistency, ideal for interferometry and high-precision fiber sensing.
TEM00 fundamental mode output with M²<1.5, superior beam focusing performance.
Universal SMA905 fiber connector with 15μm core, easy to match various optical coupling components.
Air-cooled design without water cooling system, simple equipment deployment.
DC 24V low voltage input, low overall power consumption, easy integration into automation equipment.
Less than 3% power fluctuation during long-term continuous operation, high output stability.
Compact laser head within 300×400×150mm, convenient to embed into automatic machines and experimental platforms.
10000-hour long service life design, suitable for long-duration industrial continuous operation.
Safety & Operation Notes
Operate the equipment only in well-ventilated environments between 10℃ and 35℃; do not block cooling air vents.
Never look directly into the laser output port. Wear 1550nm IR laser safety goggles during operation.
Do not sharply bend or pull the SMA905 output fiber cable with force.
Power the laser with stabilized 24V DC power supply; voltage fluctuation shall not exceed ±10%.
Store the laser in dry and dust-free environment to prevent moisture and dust from entering the laser cavity.
More information about the applications:
The application is absorption testing of coatings. Customers use the laser for generating a thermal lens on the test sample. This thermal lens is measured to calculate the absorption.